Category: 1101 power generators / Electricity producers
Latest update: 30.04.2024 add to watchlist
approved
dealer
item-No.: 161710221
New in: 2004

used

check Seller: Kandlin Stromerzeuger-Ankauf GmbH
Location: Land-de
Price: 109.000 € add to watchlist

Key data: 2613 , 3194 , 6300

2613 KW KKK condensing steam turbine Twin AFA46 GT6 from 2004 in good condition, used for sale. Manafacture: KKK Model: AFA 46 GT6 Type: Steam Condensation Serial Number: 4.746.137 Power [KW]: 2.613 Pressure inlet [bar]: 29 Temperature inlet [°C] 360 Pressure outlet [bar]: -0.8 Year of construction: 2004 Weight [kg]: – Dimensions LxWxH [cm]: – More information here: stromerzeuger-discount.de/angebote/dampfturbinen/2610-kw-kkk-twin-afa4 6-gt6/

Category: 1101 power generators / Electricity producers
Latest update: 30.04.2024 add to watchlist
approved
dealer
item-No.: 160723443
New in: 1991

used

check Seller: Kandlin Stromerzeuger-Ankauf GmbH
Location: Land-de
Price: 34.500 € add to watchlist

Key data: 825 , 975 , 400

Steam turbine Generator CCC CFR 3 G5 780 KWe x 1,500 rpm 50 Hz 400 V Turbine backpressure Manufacturer KKK Model CFR 3 G5 P drive [KW] 780 Vapor pressure [bar] 39 - 48 / 43 norm Exhaust pressure [bar] 7 - 9 / 7,85 norm Generator Manufacturer AVK Model DKBN 100M/1100-4 P Generator [KVA] 975 Revolutions [per min] 1,500 Voltage [V] 400 Current [A] 1,407 Scope of delivery: The genset consists of the turbine and the generator. Technical documentation: available Spare parts / tools: not available The genset was dismantled in a working condition Sale takes place "as is" or after prior inspection on request, FCA free.

Category: 1103 turbines
Latest update: 25.10.2023 add to watchlist
ankerimg
item-No.: 151372692
New in: 2001

used

Seller: Ahrend Consulting GmbH
Location: Land-de

add to watchlist

Biomass Plant, 5 MWel, 50 Hz, yoc 2002, in operation Boiler • Technical data: - Fuel tank capacity: approx. 1 .300 m 3 - Exhaust gas volume 29,000 Nm3/h - Average combustion temperature of 900°C (850 for 2 s.) - Thermal power of the furnace 13 MW - 2 add. Burners 5 MW each - Average calorific value Hu 12,500 kJ/kg - Throughput capacity 3,991 kg/h - Boiler working pressure 41 bar - Superheated steam temperature 420°C - designed amount of steam 14 t/h - Fuels: RDF, wood chips, straw, remains of chipboard, choiceed waste Hours of operation of the entire plant appr. 120,000 hours Steam turbine - TWIN steam turbine KKK, type: CFR 3 / AFA 6 GTA - Generator AvK, type DIG 140 k/4W - Gearbox Renk, type: ELCO W-shape can be inspected in operation this week, - SGS can be ordered for inspection.

Category: 1300 other machines and plants
Latest update: 19.12.2023 add to watchlist
approved
dealer
item-No.: 123549582

new

check Seller: Telkes Gép GmbH
Location: Land-hu
Price: 520 € add to watchlist

Manufactured by KKK Turbo family: K28-3, New!; ready for use

Category: 1107 other energy machinery
Latest update: 17.01.2024 add to watchlist
approved
dealer
item-No.: 665490
New in: 2002

used

check Seller: Ingenieurbüro Lenhart
Location: Land-de

add to watchlist

Back-pressure turbine Manufacturer: Fa. KKK First Start-up: 2002 Operating Hours of Turbine: 30,000h Type: CFR5 G6a Power Max: 2500 kW Operational efficiency: 2200 kW Revolution number: 23000 rpm Live steam pressure: 65 bar Live steam pressure temperature: 480 oC Evaporation pressure: 1-17 bar Investments in the year 2002 Entire steam transforming station from 63 bar to 2.5 bar renewed in 2002, El. Generator Leroy Somer, el. Power 2 MW Renewed measuring Entire -, governing and control of the turbine renewed Steam turbine renewed Installed boiler efficiency: Boiler I Hard coal Steam generation: 20 t/h, 63 bar, 495 oC Boiler II Hard coal Steam generation: 13 t/h, 34 bar, 425 oC Boiler III: Combination burner for oil and gas Steam generation: 20 t/h, 17 bar, 285 oC General overhaul of the entire plant from 2002 to 2004 Steam generator renewed automatic cole-loader ...

Category: 1103 turbines
Latest update: 03.05.2024 add to watchlist
approved
dealer
item-No.: 114091
New in: 2002

used

check Seller: Ingenieurbüro Lenhart
Location: Land-de

add to watchlist

Turbine Turbine mileage: 30,000 hours Counter-pressure turbine Manufacturer KKK Initial commissioning in 2002 Type: CFR5 G6a Power Max: 2500 kW Operating power: 2200 kW, Speed 23000 rpm, Fresh steam pressure: 65 bar, Fresh steam pressure temperature: 480 C, Evaporation pressure: 1-17 bar, Investments in 2002, Total steam forming station renewed from 63 bar to 2.5 bar in 2002, El. Generator Leroy Somer, el. Power 2 MW, 525 V, 2488 kVA renewed, Complete measuring, control, control technology of the turbine renewed, steam turbine renewed With Energy Installed boiler power Boiler I Coal Steam generation: 20 t/h, 63 bar, 495 C Boiler II Coal Steam generation: 13 t/h, 34 bar, 425 C Boiler III: Combined burner for oil and gas, steam generation: 20 t/h, 17 bar, 285 C General overhaul of the entire plant from 2002 to 2004, steam generator renewed, automatic charcoal and  ...

You didn't find your wanted machine? send wanted inquiry to all dealers (no registration necessary)