36,000 m3 thermal oil supply system/exhaust air purification plant
(special plant construction) WK,
Year of construction: 2012, with heat recovery and cooling supply,
The system is currently designed for two printing systems. Depending
on the
Machine equipment for 3 - 4 printing systems.
The system consists of the following components:
- 1 roof-mounted thermal post-combustion system / exhaust air
purification WK Thermal Engineering
Plant, boiler and apparatus construction WKTNV, year of construction:
2012, exhaust air volume at the inlet 36,000
m³/h,
maximum permissible combustion chamber temperature max. 730 °C,
burner type WK/H1 gas cone,
Burner power 6,600 kW, fan power 200 kW, maximum permissible inlet
temperature 210 °C,
Maximum permissible solvent throughput 500 kg/h, natural gas heating
medium, calorific value of the heating medium 32693
kJ/m³, max. heating fuel consumption 740 m³/h,
- 2 roof-mounted cooling towers M5158242 Baltimore Aircoil TXV 354,
year of construction: 2012, serial no. H 120194801/02
- 1 control panel 3R/12 IP54, serial no.: 3710236101/LTR-009,
Mounting structure, stainless steel chimney, fittings, switching,
control and regulation system
Transmitted total weight approx. 20 tons (steel weight of the system)
+ approx. 25 tons (steel construction)
The TNV can also be operated alone without the refrigeration system.