Execution:
Aggregate type:
stationary
Execution:
Soundproofed
Technical data engine:
Engine manufacturer:
MTU
Engine:
10V1600G20F-3B
Engine No.:
on request
Power:
430 KW
Cooling:
Water-cooled
Occasion:
Electric 24 V DC
Speed:
1500 rpm
Fuel:
Fuel oil EN 590 / Diesel B 7
Technical data generator:
Generator manufacturer:
Stamford AvK
Generator type:
HCI 544 D
Gene. No.:
in production
Generator power:
550 kVA
Voltage:
400 / 231 Volt
Power factor:
Cos. - PHI 0.8
Speed:
1500 rpm
Switchgear:
Execution:
Automatic start
Functions:
Parallel operation
Switch:
Generator switch 4 poles
Delivery:
Built
Tank:
Execution:
Base frame tank with drip pan
Content / liter:
990
Dimensions of the power unit:
Width approx. mm:
2.060
Height approx. mm:
2.585
Length approx. mm:
4.860
Weight approx. KG:
6.000
Stock number:
1384
Condition:
New
Year of construction:
2023
Delivery period:
4 Q / 2023
Hours:
0
Location:
Verl - Germany
Scope of delivery:
Soundproofed emergency power system NEA for outdoor installation as a
backup power supply with a nominal output of 550 kVA with MTU motor 10
V 1600 G 20 F grid-parallel
The built-in emergency power control is designed for uninterruptible
back-synchronization, overlap synchronization, with control of your
on-site mains-generator switching.
Internal day A5168 tank (990 litres) in the base frame with drip pan.
Optionally with leakage monitoring
Fuel consumption according to MTU data sheet:
Fuel consumption 50% l./h 58
Fuel consumption 75% l./h 79
Fuel consumption 100% l./h 102
Autonomy at 75% of load h. ≈ 12 h
-/-
Engine fluids and equipment
Type Lubricant Oil SAE 15W40
Lubricating oil quantity: 60 litres
Battery Capacity Ah 180
Number of batteries 2 x 12 volt
-/-
Air data & energy balance:
Combustion air flow PRP: 1620 m3/h
Cooling air flow PRP: 34,920 m3/h
Exhaust gas flow PRP: 4,500 m3/h
Exhaust gas temperature PRP: 520 °C
Max. exhaust gas back pressure mbar: 85