Execution:
Aggregate type:
stationary
Execution:
Soundproofed
Technical data engine:
Engine manufacturer:
Deutz
Engine:
BF 4 M 2011 C
Engine No.:
on request
Power:
53.3 KW
Cooling:
Oil-cooled
Occasion:
Electric 12 V DC
Speed:
1500 rpm
Fuel:
Fuel oil EN 590
Technical data generator:
Generator manufacturer:
Stamford AvK
Generator type:
Synchronous with AVR
Gene. No.:
on request
Generator power:
60 kVA
Voltage:
400 / 231 Volt
Power factor:
Cos. - PHI 0.8
Speed:
1500 rpm
Switchgear:
Execution:
Automatic start
Functions:
Hand & Remote Start
Switch:
Generator switch 4 poles
Delivery:
Built
Tank:
Execution:
Base frame tank with drip pan
Content / liter:
270
Condition:
New
Year of construction:
2023
Delivery period:
Instant Verl
Hours:
1
Location:
Verl - Germany
Scope of delivery:
General equipment emergency generator TYPE WA DG 60 "S" 270 L | RAL
7046
Soundproofed backup power system with the following features:
Emergency generator as a backup power supply for your emergency power
supply with an original 4 cylinder Deutz industrial diesel engine with
mechanical speed control and Stamford three-phase synchronous
generator. The motor and generator are elastically mounted on a common
skid frame. Exhaust system insulated with mineral fibre sheathing.
Installed in a modular soundproofing enclosure. Powder-coated in RAL
7046 tele grey
----------------------------------------------------------------------
-----------------------------
Fuel consumption according to Deutz data sheet:
6.49 litres at 50% load | Runtime with full tank approx. 41.6 hours
9.74 litres at 75% load | Runtime with full tank approx. 27.7 hours
13.2 litres at 100% load | Runtime with full tank approx. 20 hours
----------------------------------------------------------------------
-----------------------------
Internal automatic start-stop system (type: AMF DSE 4150) with display
of all important engine and generator messages. Functional display
digitally on the display. Generator switch 100 amps 4 poles integrated
on the aggregate (switchgear). Internal battery charger 230 volts –
12 volts DC
Optionally A5368 available at an additional cost (1,620 euros
net):
Automatic start with grid & generator switching 4 poles | 90 amps
External emergency power switchgear for installation in the building
and 4-pole mains generator switching
Function: In the event of a power failure, the start command is
transferred to the diesel generator. When the nominal speed and
nominal voltage are reached, the generator switch is switched on. In
the event of a return to the mains, the automatic system monitors the
mains voltage. When this is stable again, the switch back to mains
operation takes place. The diesel generator is stopped after the
cooling time and waits in automatic mode for the next power
failure.
Optional, available at an additional cost: (subject to
availability)
1 x CEE socket 125 ampere 1H coded, required for building supply
according to VDE 0100-551
The emergency power system as an emergency power supply is ready for
operation and immediately available from the Verl warehouse.