Reven Wall Extractor Hood X-CYCLONE® EGU-SERIES
This exhaust hood works according to the recirculation principle. The
cleaned exhaust air is fed back into the room as a supply air flow.
An exhaust duct is not required
X-CYCLONE® recirculating hood with a separation efficiency of up to
99.9999 %
Flame penetration resistance tested according to international
standards
with integrated odour filter
Stainless steel hood frame with integrated low-speed air outlet
Special perforated air outlet for temperature-controlled air supply on
the long side of the hood
all cut edges are folded and burr-free
Aerosol separator installed at an inclined position in accordance with
DIN EN 16282
The separators and Blanc panels can be removed without tools and are
suitable for cleaning in the dishwasher
Emptying of the grease collection channel at a deep-drawn point by
means of a grease drain valve with internal thread
Entire design according to DIN EN 16282, VDI 2052 and BGR 111
(Workplace Ordinance)
Corrosion resistance is guaranteed by manufacturing processes in
accordance with the regulations of the trademark association Edelstahl
Rostfrei e.V
Development, design and production according to the SNS principle.
The hood is equipped with X-CYCLONE® Basic separator elements, RGN99
odour filters and a fan with step control.
Recirculation operation according to VDI 2052
Manufacturer: Rentschler REVEN K5327004 GmbH
Type: X-CYCLONE® Detection Hood EGU
Material: Stainless steel 1.4301
Surface: Fine sanding, grit 180, sanded on one side
Mounting: Wall version
5 levels of control
Integrated lighting
2 pcs Aerosol Separator Basic Element Type X-CYCLONE®
1 built-in fan EBM PAPST D2E160GL0701, up to 1,100 m³/h
1 pc grease drain tap
Air volume: 1000 m³/h
Length: 1000 mm
Width: 1000 mm
Height: 700 mm
Number of separators: 2
Voltage: 1~230V
Electricity: 0.5 KW
Sound emission: 67 dB(A)
Operating instructions
More items - new and used - can be found in our shop!
International shipping costs on request!