: 400 V / 50 Hz
: < 75 dB(A)
power capacity: 15
kW
volume capacity: 20.000 m³/h
weight: 1590 kg
Modular
plug & play airtower
for hall extraction of welding fumes with
integrated, soundproofed
Fan, automatic, differential pressure
controlled
Filter cleaning, system control with color display,
particle pre-separation and
IFA - tested filter cartridges. The
system is for a volume flow of
average 20,000 m³ / h
designed
1st filter stage - main filter:
Filter area: 222
m²
Number of filters: 6 pieces
Dust class according to DIN
EN
60335-2-69: M.
Degree of separation:> 99.9%
Cleaning:
Jet - Pulse
Compressed air connection: NW 7.2 mm,
4-6 bar, oil
and water free
2nd filter stage - fine dust filter.
Filter
area: 65 m²
Filter class according to ISO 16890: ISO
ePM1
80%
3rd filter stage -
Synthetic fiber mats:
Filter area:
8 m²
Filter class according to ISO 16890: H5151851
ISO
coarse 60%
Total filter area: 295
m²
Dimensions:
Width filter unit: 2,066 mm
Depth filter
unit: 1,756 mm
Height of filter unit: 3,643 mm
Dust container:
200 liters
Version Sanders incl .:
- NOVUS efficiency
package FT20.000
- timer
- NOVUS particle sensor
The data for this ad was created with
ModulMWS - the software solution of LogoTech oHG.