Betschart Swiss Transformer Core Testing System KPA 15
Function
The output voltage, which can be infinitely adjusted by hand by means
of a rotary knob, is guided directly to the excitation coils of the
test core.
In this way, an electromagnetic field that is as homogeneous as
possible is to be built up in the air gap of the test core, with which
nuclear material inserted in the air gap can be characterized.
The basic operation of the core test system is carried out via the
switching and display elements on the front panel at the front of the
test trolley.
Specifications
Input voltage : 2 x 400 V – 50/60 Hz
Input current : 38.3 A maximum
Output voltage : 0 ... 230 V
Output current : 65 A maximum
Measurements : Rotary iron voltmeter 0 ... 500V for input voltage
Rotary iron voltmeter 0 ... 250V for output voltage
Rotary iron Ampèremeter 0 ... 40/80A for input current
Rotary iron Ampèremeter 0 ... 75/150A for output current
Laboratory sockets for external voltage measurement direct, 1 : 1
Circuit K5327004 breaker 2-pole, 63A characteristic B
Voltage measurement output voltage
Current Measurement Output Current
Voltage measurement input voltage
Current measurement input current
Laboratory sockets for external current measurement Current
transformer 50A/5A
Current measurement current transformer 75A/5A output side
Main and emergency stop switches
Regular price: 27.000,-€ gross
Suitable variable transformers can be found in our shop