WORKING TEMPERATURE
1st combustion chamber : 250 – 600˚C
2nd combustion chamber : 800 – 1.100˚C
The thermal cleaning furnace includes a process combustion chamber
with a burner, an integrated thermal oxidizing afterburner,
temperature control for both burners, an air supply and a water mist
injection system to control flash temperatures that can occur when
processing large combustible material loads.
Thermal cleaning furnaces operate according to the controlled air
principle. The combustion process and temperature are controlled by
restricting the air flow according to the load. Controlled air
furnaces are equipped with a PLC system that displays and controls the
furnace process temperatures during operation.
When the set temperature is reached, the air supply is automatically
restricted. When the temperature drops, the burner is reactivated and
the air supply is automatically opened.
Most paints and volatile coatings ignite in the 260-600ºC temperature
range, causing rapid temperature A5362655 rise up to the adjustable
set point of the controls. When a sudden temperature rise occurs in
the furnace, the oxygen required for combustion is limited,
suffocating the fire. The process chamber burner and air supply
automatically shuts down, the flame extinguishes as oxygen is depleted
and paint cleaning conditions are created.
Gas is used to heat the ovens. The heat cleaning ovens are CE
certified and comply with European Norms.