heat and power plant HEAT AND POWER PLANT WITH AN ABSORPTION 850 kW

energy & engines: power generators, engines, turbines, boilers / power generators

Manufacturer: HEAT AND POWER PLANT WITH AN ABSORPTION

Model:850 kW

Type of machine: heat and power plant

item-No.: 166201280

Quantity: 1

Date: 09.01.2025

Location: Nuremberg, Germany

Price:


Seller-item-No.:5497160

Heat and Power Plant with an Absorption Chiller

An 850 kW combined heat and power plant with an absorption chiller.

The systems ran perfectly until the end and all maintenance was carried out.

No damage is known.

The CHP ran for 51,429 hours of operation.

The absorption chiller has run for 42,350 hours.

The following components use an overhauled long block or completely overhauled. The components relevant to assemblies for "modernization" were marked:

- complete panelling

- Interfaceschronk

- Oil relubrication pump

Mechanically overhauled and electrically tested

- Oil level monitoring

- Plotter heat exchanger"

- Pressure expansion foll3 (if present)

- Pressure transducer and temperature sensors

- Rubber rails for motor and generator

- Clutch element

- Air filter inserts

- Safety valves and arnot inserts

- Sylomer strips

- Hot water preheating pump and heating element

- Test run with performance and efficiency measurement

- Loosening

- Updated spare parts list and new circuit diagram

Optional:

- Generator (suitable for grid code)

- Exhaust gas heat exchanger

- Gas pressure control line"

- Integration new I pipework, module frame )

- Dia.ne XT3 module controller

- Complete documentation (maintenance log, descriptions, U5158834 techn,

technical diagram, unit drawing )

Not included:

- Seals and connection parts on site

Motor type

JMC 316 GS-N.LC

Electrical output per unit: 835 kW

Thermal output per unit: 986 kW

Frequency: 50 Hz

Voltage: 400 V

Emissions according to valid TA Luft: NOx 500 mg/Nm 3

co 300 mg/Nm 3

The system is operated with natural gas in accordance with the technical instructions TA 1000-0300.

electrical output 850 kW el.

thermal output 945 kW Emission values

NOx < 500 mg/Nm3 (5% 02)

CO < 300 mg/Nm3 (5% 02)

Find more here - /

Contact us at -
Share this machine on Facebook:

Inquiry

Machinery dealer?

Please remit optionally

Send wanted inquiry?

Copy to you?

Save input data

Heat and Power Plant with an Absorption Chiller

An 850 kW combined heat and power plant with an absorption chiller.

The systems ran perfectly until the end and all maintenance was carried out.

No damage is known.

The CHP ran for 51,429 hours of operation.

The absorption chiller has run for 42,350 hours.

The following components use an overhauled long block or completely overhauled. The components relevant to assemblies for "modernization" were marked:

- complete panelling

- Interfaceschronk

- Oil relubrication pump

Mechanically overhauled and electrically tested

- Oil level monitoring

- Plotter heat exchanger"

- Pressure expansion foll3 (if present)

- Pressure transducer and temperature sensors

- Rubber rails for motor and generator

- Clutch element

- Air filter inserts

- Safety valves and arnot inserts

- Sylomer strips

- Hot water preheating pump and heating element

- Test run with performance and efficiency measurement

- Loosening

- Updated spare parts list and new circuit diagram

Optional:

- Generator (suitable for grid code)

- Exhaust gas heat exchanger

- Gas pressure control line"

- Integration new I pipework, module frame )

- Dia.ne XT3 module controller

- Complete documentation (maintenance log, descriptions, U5158834 techn,

technical diagram, U5158834 unit drawing )

Not included:

- Seals and connection parts on site

Motor type

JMC 316 GS-N.LC

Electrical output per unit: 835 kW

Thermal output per unit: 986 kW

Frequency: 50 Hz

Voltage: 400 V

Emissions according to valid TA Luft: NOx 500 mg/Nm 3

co 300 mg/Nm 3

The system is operated with natural gas in accordance with the technical instructions TA 1000-0300.

electrical output 850 kW el.

thermal output 945 kW Emission values

NOx < 500 mg/Nm3 (5% 02)

CO < 300 mg/Nm3 (5% 02)

Find more here - /

Contact us at -
seller offer No. resale 5497160
Share this machine on Facebook:

Verkäufer

logo dealer

UCY Industrial GmbH

Mr Nick Breinfalk
82049 Pullach
Germany

RESALE member since 2024

  • machine list (1455)

Inquiry

Machinery dealer?

Please remit optionally

Send wanted inquiry?

(to all dealers for such a machine)

Copy to you?

(copy of your inquiry will be sent to your email address)

Save input data

(Save input data for further inquiries)