We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
General SKU394U1112 LocationBarneveld MakeLauda TypeTR400 HK/KT-EX Mach.No.HSK08023 Pressure Working pressure16 Bar Main Features Heating (medium)Oil Capacity12.9 KW Temp.200 °C Specified Features - Temperature control unit MaterialStainless steel 1.4571 (316Ti) Temperating machinecheck Thermal oil heatercheck Therminol D12 Heating medium:Oil Electric capacity12,9 kW, 400 volt (Ex) Temperature-40°C/+200°C With pumpcheck (2x) Capacity18m²/h Motor5,5kW, 400/690 Volt, 2880rpm (EX) (2x) Information Year of construction2008 With switchcheck CEcheck Floorspace1,75x1,0 m Total height2,50 m Weight1800 kg ATEX compatiblecheckTemperature control unitsLaudaHeat exchang ...
General SKU394U1114 LocationBarneveld MakeLauda TypeTR 400 HK/KT-EX Mach.No.HKS08022 Pressure Working pressure3 Bar Main Features Heating (medium)Oil Capacity12.9 KW Temp.200 °C Specified Features - Temperature control unit MaterialStainless steel 1.4571 (316Ti) Thermal oil heatercheck (Therminol D12) Heating medium:Oil Electric capacity12,9 kW, 400 volt (ex) Temperature-40°C/200°C With pumpcheck (2x) Capacity18 m³/h Motor5,5 kW, 400/690 volt, 2925 rpm (EX) (2x) Information Year of construction2008 Total height2,50 m CEcheck Floorspace1,75x1,00 m Weight1800 kg ATEX compatiblecheckTemperature control unitsLaudaHeat exchangers > Temperature control unitsBrand > ...
General SKU394U1111 LocationBarneveld MakeLauda TypeTR400HK/K-EX Mach.No.HSK13074 Pressure Working pressure3 Bar Main Features Heating (medium)Oil Capacity12.46 KW Temp.130 °C Specified Features - Temperature control unit MaterialStainless steel 1.4571 (316Ti) Thermal oil heatercheck (Therminol D12) Electric capacity12,46 kW, 400 volt, , (Ex) Temperature-35/130 ºC With pumpcheck (2x) Capacity18 m³/h Motor5,5 kW, 400/690 volt, 2925 rpm (EX) (2x) Information Year of construction2013 With switchcheck CEcheck Floorspace1,75x1,0 m Total height2,5 m Weight1800 kg ATEX compatiblecheckTemperature control unitsLaudaHeat exchangers > Temperature control unitsBrand > Laud ...
General SKU394U1115 LocationBarneveld MakeLauda TypeTR400 HK/KT-EX Mach.No.HKS08021 Pressure Working pressure16 Bar Main Features Heating (medium)Oil Capacity12.9 KW Temp.200 °C Specified Features - Temperature control unit Thermal oil heaterTherminol D12 Heating medium:Oil Electric capacity12.9 kW, 400 volt (ex) Temperature-40°C/+200°C With pumpcheck (2x) Capacity18m²/h Motor5,5kW, 400/690 Volt, 2880 rpm (EX) (2x) MaterialStainless steel 1.4571 (316Ti) Information Year of construction2008 Total height2,50 m CEcheck Floorspace1,75x1,0 m Weight1800 kg ATEX compatiblecheckTemperature control unitsLaudaHeat exchangers > Temperature control unitsBrand > Lauda What ...
General SKU394U1120 LocationBarneveld MakeLauda TypeTR 400 HK/HK-EX Mach.No.HKS08026 Pressure Working pressure16 Bar Main Features Heating (medium)Oil Capacity12.9 KW Temp.200 °C Specified Features - Temperature control unit MaterialStainless steel 1.4571 (316Ti) Thermal oil heatercheck Therminol D12 Heating medium:Oil Electric capacity12.9 kW, 400 volt Temperature-40°C/+200°C With pumpcheck 2x Capacity18m²/h Motor5,5kW, 400/690Volt, (EX) Information Year of construction2008 Total height2,50 m CEcheck Floorspace1,75x1,0 m Weight1800 kg ATEX compatiblecheckTemperature control unitsLaudaHeat exchangers > Temperature control unitsBrand > Lauda What you can expect ...
General SKU394U1127 LocationBarneveld MakeLauda TypeTR 400 K-EX Mach.No.HKS08034 Pressure Working pressure16 Bar Main Features Heating (medium)Oil Capacity6.45 KW Temp.200 °C Specified Features - Temperature control unit MaterialStainless steel 1.4571 (316Ti) Thermal oil heaterTherminol D12 Heating medium:Oil Electric capacity6,45 kW, 400Volt. (EX) Temperature-40°C/+200°C With pumpcheck Capacityunknown Motor5,5kW, 400/690 Volt, 2880 rpm (EX) Information Year of construction2008 Mounted on framecheck CEcheck Floorspace1,75x1,00 m Total height1,70 m ATEX compatiblecheckTemperature control unitsLaudaHeat exchangers > Temperature control unitsBrand > Lauda What you ...
General SKU394U1126 LocationBarneveld MakeLauda TypeTR400 HKT/HKT-EX Mach.No.HKS08033 Pressure Working pressure16 Bar Main Features Heating (medium)Oil Capacity12.9 KW Temp.200 °C Specified Features - Temperature control unit MaterialStainless steel 1.4571 (316Ti) Thermal oil heatercheck Therminol D12 Heating medium:Oil Electric capacity 12,9 kW, 400 volt (ex) Temperature-40°C/+200°C With pumpcheck(2x) Capacity18m²/h Motor5,5 kW, 400/690 Volt, 2880 rpm (EX) (2x) Information Year of construction2008 CEcheck Floorspace2,15x1,0 m Total height2,50 m ATEX compatiblecheckTemperature control unitsLaudaHeat exchangers > Temperature control unitsBrand > Lauda What you c ...
General SKU394U1122 LocationBarneveld MakeLauda TypeTR400 HK/HK-EX Mach.No.HKS08027 Pressure Working pressure16 Bar Main Features Heating (medium)Oil Capacity12.9 KW Temp.200 °C Specified Features - Temperature control unit MaterialStainless steel 1.4571 (316Ti) Temperating machinecheck Thermal oil heaterTherminol D12 Heating medium:Oil Electric capacity12.9 kW, 400 volt (ex) Temperature-40°C/+200°C With pumpcheck (2x) Capacity18m²/h Motor5,5kW, 400/690 Volt, 2880 rpm (ex) (2x) Information Year of construction2008 Total height2,50 m CEcheck Floorspace1,75x1,0 m Weight1800 kg ATEX compatiblecheckTemperature control unitsLaudaHeat exchangers > Temperature contr ...
General SKU394U1110 LocationBarneveld MakeLauda TypeTR400 HK/K-EX Mach.No.HKS13075 Pressure Working pressure10 Bar Main Features Heating (medium)Oil Capacity12.46 KW Temp.130 °C Specified Features - Temperature control unit MaterialStainless steel 1.4571 (316Ti) Thermal oil heatercheck Therminol D12 Heating medium:oil Electric capacity12,46 kW, 400 volt (Ex) Temperature-35ºC/+130ºC With pumpcheck 2x Capacity18m²/h Motor5,5kW, 400/690Volt, 2925rpm (EX) (2x) Information Year of construction2013 With switchcheck CEcheck Floorspace1,75x1,0 m Total height2,45 m Weight1800 kg ATEX compatiblecheckTemperature control unitsLaudaHeat exchangers > Temperature control un ...
General SKU394U1121 LocationBarneveld MakeLauda TypeTR400 HK/HK-EX Mach.No.HKS08025 Pressure Working pressure16 Bar Main Features Heating (medium)Oil Capacity12.9 KW Temp.200 °C Specified Features - Temperature control unit MaterialStainless steel 1.4571 (316Ti) Temperating machinecheck Thermal oil heaterTherminol D12 Heating medium:Oil Electric capacity12.9 kW, 400 volt (ex) Temperature-40°C/+200°C With pumpcheck (2x) Motor5,5 kW, 400/690 volt, 2800 (ex) Information Year of construction2008 Total height2,50 m CEcheck Floorspace1,75x1,0 m Weight1800 kg ATEX compatiblecheckTemperature control unitsLaudaHeat exchangers > Temperature control unitsBrand > Lauda Wha ...