Process chiller / chiller air-cooled, Type: Aries TECH AST 120 SHE MTA S.p.A. The Aries TECH AST 120 SHE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with shell-and-tube evaporator, four scroll compressors, compressor shut-off valves, crank tray heater, phase monitoring, P2 pump, 600 litre tank, electric antifreeze heater, condenser filter and control and control cabinet. Cooling capacity (kW): 278 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 47.6 Available. Pump pressure (bar): 2.49 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quantity): 2 Compressors (quantity): 4 ...
Process chiller / chiller air-cooled, Type: - Aries TECH AST 100 SHE – 215 kW Refrigeration Machines, MTA S.p.A. The Aries TECH AST 100 SHE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with shell-and-tube evaporator, four scroll compressors, compressor shut-off valves, crank pan heater, phase monitoring, P2 pump, 400 litre tank, electric antifreeze heater, condenser filter and control and control cabinet. Cooling capacity (kW): 215 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 36.9 Available. Pump pressure (bar): 2.6 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quanti ...
Process chiller / chiller air-cooled, Type: Aries TECH AST 120 SHE MTA S.p.A. The Aries TECH AST 120 SHE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with shell-and-tube evaporator, four scroll compressors, compressor shut-off valves, crank tray heater, phase monitoring, P2 pump, 600 litre tank, electric antifreeze heater, condenser filter and control and control cabinet. Cooling capacity (kW): 278 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 47.6 Available. Pump pressure (bar): 2.49 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quantity): 2 Compressors (quantity): 4 ...
Process chiller / chiller air-cooled, Type: - Aries TECH AST 100 SHE – 215 kW Refrigeration Machines, MTA S.p.A. The Aries TECH AST 100 SHE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with shell-and-tube evaporator, four scroll compressors, compressor shut-off valves, crank pan heater, phase monitoring, P2 pump, 400 litre tank, electric antifreeze heater, condenser filter and control and control cabinet. Cooling capacity (kW): 215 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 36.9 Available. Pump pressure (bar): 2.6 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quanti ...
Process water chiller / chiller / chiller water cooled, Type: TWEevo Tech 381 P3 MTA S.p.A. TWEevo Tech 381 P3 are air-cooled compact water chillers that are suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 60 ltr., built-in P3 pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 72.2 [20.5 tons cooling] Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 12.3 Available pump pressure (bar) 3.46 Cooling water temp. Outlet/Entry (°C): 45 / 40 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 39 ...
Heat pump / chiller air-cooled, Type: Taurus TECH HTAT 040 HE MTA S.p.A. Heat pump / chiller Taurus TECH HTAT 040 HE (reversible) with hydronic kit, storage tank + pump P15 + fairing hydraulics. Heating capacity kW 99.3 Cold water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 17.2 Available pump pressure bar 0.966 Ambient temperature +7 °C Cooling capacity kW 84.5 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 14.4 Available pump pressure bar 1.24 Ambient temperature 32 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 47 Max. current (A) 79 Starting current circuit (A) 263 Protection class: IP ...
Heat pump / chiller - switchable - water / water cooled, Type: OCEAN Tech HOCT 200 MTA S.p.A. OCEAN Tech HOCT 200 are water-cooled heat pump / chiller for indoor installation without hydraulic circuit (pump, accumulator) incl. crank pan heating, phase monitoring. An external dry cooler unit is not included in the offer. Cooling capacity kW 53.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.25 Cooling water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 13.5 Heating capacity kW 67.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.51 Cooling water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 11.7 Refrigerant R 410A Electrical data: Voltage V 400, ...
Heat pump / chiller - switchable - water / water cooled, Type: OCEAN Tech HOCT 200 MTA S.p.A. OCEAN Tech HOCT 200 are water-cooled heat pump / chiller for indoor installation without hydraulic circuit (pump, accumulator) incl. crank pan heating, phase monitoring. An external dry cooler unit is not included in the offer. Cooling capacity kW 53.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.25 Cooling water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 13.5 Heating capacity kW 67.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.51 Cooling water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 11.7 Refrigerant R 410A Electrical data: Voltage V 400, ...
Process chiller / chiller water-cooled, Type: AQUARIUS PLUS 2 – AQP2 2601 MTA S.p.A. The Phönix AQUARIUS PLUS 2 – AQP2 2601 are water-to-water chillers for indoor installation. Shell-and-tube evaporators, Handbell screw compressors with infinitely variable capacity control, control and switch cabinet incl. Vitaulic couplings. Cooling capacity (kW): 654 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 112 Cooling water temp. Exit/Entry (°C): 35 / 30 Flow rate (m³/h): 134 Refrigeration circuit: Refrigerant R 134A Number of refrigeration circuits: 1 Total number of compressors: 1 Power levels (%): 0-25 infinitely variable up to 100 Electrical data: ...
Chiller (cooling) unit Supplier: MTA (Italy) Type: TAE161-EVO 21 Kw Max. allowed pressure: 28 BAR Dimension: 18008001200 mm (LWH) Weight: 416 kg ...