We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Process chiller / chiller water-cooled, Type: AQUARIUS PLUS 2 – AQP2 2601 MTA S.p.A. The Phönix AQUARIUS PLUS 2 – AQP2 2601 are water-to-water chillers for indoor installation. Shell-and-tube evaporators, Handbell screw compressors with infinitely variable capacity control, control and switch cabinet incl. Vitaulic couplings. Cooling capacity (kW): 654 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 112 Cooling water temp. Exit/Entry (°C): 35 / 30 Flow rate (m³/h): 134 Refrigeration circuit: Refrigerant R 134A Number of refrigeration circuits: 1 Total number of compressors: 1 Power levels (%): 0-25 infinitely variable up to 100 Electrical data: ...
Process chiller / chiller water-cooled, Type: AQUARIUS PLUS 2 – AQP2 2601 MTA S.p.A. The Phönix AQUARIUS PLUS 2 – AQP2 2601 are water-to-water chillers for indoor installation. Shell-and-tube evaporators, Handbell screw compressors with infinitely variable capacity control, control and switch cabinet incl. Vitaulic couplings. Cooling capacity (kW): 654 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 112 Cooling water temp. Exit/Entry (°C): 35 / 30 Flow rate (m³/h): 134 Refrigeration circuit: Refrigerant R 134A Number of refrigeration circuits: 1 Total number of compressors: 1 Power levels (%): 0-25 infinitely variable up to 100 Electrical data: ...
Chiller (cooling) unit Supplier: MTA (Italy) Type: TAE161-EVO 21 Kw Max. allowed pressure: 28 BAR Dimension: 18008001200 mm (LWH) Weight: 416 kg ...
Process water chiller / chiller / chiller water cooled, Type: TWEevo Tech 381 P3 MTA S.p.A. TWEevo Tech 381 P3 are air-cooled compact water chillers that are suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 60 ltr., built-in P3 pump. Cold water outlet temperatures from -10°C to +30°C can be adjusted. Cooling capacity kW 72.2 [20.5 tons cooling] Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 12.3 Available pump pressure (bar) 3.46 Cooling water temp. Outlet/Entry (°C): 45 / 40 Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 39 ...
Process chiller / chiller air-cooled, Type: HAries G - HASG2 210 SHE (special) MTA S.p.A. The Aries HASG2 210 SHE are compact chilled water chillers designed for outdoor installation (from -20°C to +47°C) are suitable with crank tray heating, phase monitoring, tube bundle evaporator, 6 scroll compressors, , electr. Expansion valves, shut-off valves compressors, storage tank, P2 double pump, electric antifreeze heater, condenser filter, winter control with speed-controlled fans and control and control cabinet. Cooling capacity (kW): 544 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 93 Available pump pressure (bar): 2.45 Ambient Temperature (°C): 32 Refrig ...
Process chiller / chiller water-cooled, Type: AQUARIUS PLUS 2 – AQP2 2601 MTA S.p.A. The Phoenix AQUARIUS PLUS 2 – AQP2 2601 are water / water chillers for indoor installation. Shell and tube evaporator, handbell screw compressors with infinitely variable capacity control, control and control cabinet incl. Vitaulic couplings. Cooling capacity (kW): 654 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 112 Cooling water temp. Exit/Entry (°C): 35 / 30 Volume flow (m³/h): 134 Refrigeration circuit: Refrigerant R 134A Refrigeration Circuits (Quantity): 1 Compressors (quantity): 1 Power levels (%): 0-25 infinitely variable up to 100 Electrical data: Vo ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 602 P3 MTA S.p.A. TAEevo Tech 602P3 are compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, electronic expansion valve, buffer tank 500 ltr., built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 116 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 19.8 Available pump pressure (bar) 3.37 Ambient temperature °C 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 60.99 Max. current (A) 102.78 Starting Current Ci ...
Process chiller / chiller air-cooled, Type: Phoenix PNG2 6402 SSN M.T.A. S.p.A. The Phönix PNG2 6402 SSN are inverter controlled compact chillers that are suitable for outdoor installation. - Shell-and-tube evaporators, - Electronic Explosion Valves - Shut-off valves for compressors, - Equipment for low ambient temperatures down to -20°C with EC fans - Housing cladding, - condenser filter mats, - Control and control cabinet - Vitaulic couplings. Cooling capacity (kW): 695 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 119 Evaporator pressure loss bar: 0.228 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R513A, GWP 631, safety ...
Process chiller / chiller air-cooled, Type: Aries TECH AST 120 SHE MTA S.p.A. The Aries TECH AST 120 SHE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with shell-and-tube evaporator, four scroll compressors, compressor shut-off valves, crank tray heater, phase monitoring, P2 pump, 600 litre tank, electric antifreeze heater, condenser filter and control and control cabinet. Cooling capacity (kW): 278 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 47.6 Available. Pump pressure (bar): 2.49 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quantity): 2 Compressors (quantity): 4 ...
Process Air Cooler/Chiller/Chiller Air Cooled, Type: TAEevo Tech 502 P3 Refrigeration Machines, MTA S.p.A. TAEevo Tech 502P3 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 500 ltr., built-in P3 Circulation pump and condenser pressure control. Cooling capacity kW 105 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 17.9 Available pump pressure (bar) 3.42 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 55.49 Max. current (A) 93.47 Starting Current Circuit (A) 192.06 ...