item-No.: 164666869 is deleted from the database!

10 similar machines:

approved
dealer
Machine: MTA TAEevoTech 161P3 - 38,6 kW
New in: 2023
used

Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 161 P3 MTA S.p.A. TAEevo Tech 161 are air-cooled compact water chillers that are suitable for outdoor installation. Including crank pan heating, phase monitoring, buffer tank 255 ltr. and built-in P3 Circulating pump. Cooling capacity kW 38.6 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 6.58 Available pump pressure (bar) 2.59 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 21 Max. current (A) 36 Starting Current Circuit (A) 204 Protection class: IP54 Dimensions: Length (mm) 1862, Width (m ...

approved
dealer
Machine: MTA TAEevoTech 802P3-2 - 159 kW
New in: 2020
used

Process chiller / chiller air-cooled, Type: TAEevo Tech 802 P3-20 MTA S.p.A. TAEevo Tech 802 P3-20 are air-cooled compact water chillers suitable for outdoor installation (from -20°C to +46°C). Including crank pan heating, phase monitoring, electronic injection valves, buffer tank 678 ltr. and built-in P3 circulation pump. Cooling capacity kW 159 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 27.1 Available pump pressure (bar) 3.13 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 79.48 Max. Current (A) 142.2 Starting Current Circuit (A) 286.2 Protection class: IP5 ...

approved
dealer
Machine: MTA TAEevoTech 381 P3-20 - 80,4 kW
New in: 2022
new

Process chiller / chiller air-cooled, Type: TAEevo Tech 381 P3-20 MTA S.p.A. TAEevo Tech 381 P3-20 are air-cooled compact water chillers suitable for outdoor installation (-20 to +46°C). Including crank pan heater, phase monitoring, buffer tank 410 ltr., built-in P3 Circulating pump and winter package (control cabinet heating + speed-controlled fans) Cooling capacity kW: 80.4 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 13.7 Available pump pressure (bar): 3.46 Ambient temperature (°C): 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 42 Max. current (A) 75 Starting Current Circuit (A)  ...

approved
dealer
Machine: MTA TAEevoTech 015 P3 - 5,32 kW
New in: 2019
used

Process chiller / chiller air-cooled, Type: TAEevo Tech 015 P3 MTA S.p.A. TAEevo Tech 015 P3 are air-cooled compact water chillers suitable for indoor installation. Including crank pan heating, phase monitoring, buffer tank 60 ltr., built-in P3 Circulating pump. Suitable for operation with aggressive process fluids. Cooling capacity kW 5.32 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 0.911 Available pump pressure (bar) 2.93 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 3.8 Max. current (A) 6.53 Starting Current Circuit (A) 27.65 Protection class: IP44 Dime ...

approved
dealer
Machine: MTA TAEevoTech 015 P3 - 5,32 kW
New in: 2019
used

Process chiller / chiller air-cooled, Type: TAEevo Tech 015 P3 MTA S.p.A. TAEevo Tech 015 P3 are air-cooled compact water chillers suitable for indoor installation. Including crank pan heating, phase monitoring, buffer tank 60 ltr., built-in P3 Circulating pump. Suitable for operation with aggressive process fluids. Cooling capacity kW 5.32 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 0.911 Available pump pressure (bar) 2.93 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 3.8 Max. current (A) 6.53 Starting Current Circuit (A) 27.65 Protection class: IP44 Dime ...

approved
dealer
Machine: MTA Chiller
used
Seller: Land-uk Andrew Isaacs Machinery International Ltd
VS

Chiller (cooling) unit Supplier: MTA (Italy) Type: TAE161-EVO 21 Kw Max. allowed pressure: 28 BAR Dimension: 18008001200 mm (LWH) Weight: 416 kg  ...

  • more information

approved
dealer
Machine: MTA 123 kW
used
Seller: Land-it STOCKEUROSTOCK SRL
Location:: 44100 Ferrara

No. 2 MTA brand chillers 3 mt. x 2 x about 1, in good condition + one/two augers for industrial use, stainless steel. Cooling capacity 123 kW. Both chillers have a CE certificate of conformity issued in 2011. Dimensions: over 3 meters long and over 2 meters high - weight about 1600 kg.  ...

  • more information

approved
dealer
Machine: MTA Taurus TECH HTAT 040 HE
New in: 2022
new

Heat pump / chiller air-cooled, Type: Taurus TECH HTAT 040 HE MTA S.p.A. Heat pump / chiller Taurus TECH HTAT 040 HE (reversible) with hydronic kit, storage tank + pump P15 + fairing hydraulics. Heating capacity kW 99.3 Cold water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 17.2 Available pump pressure bar 0.966 Ambient temperature +7 °C Cooling capacity kW 84.5 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 14.4 Available pump pressure bar 1.24 Ambient temperature 32 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 47 Max. current (A) 79 Starting current circuit (A) 263 Protection class: IP ...

approved
dealer
Machine: MTA OCEAN Tech HOCT 200
New in: 2022
new

Heat pump / chiller - switchable - water / water cooled, Type: OCEAN Tech HOCT 200 MTA S.p.A. OCEAN Tech HOCT 200 are water-cooled heat pump / chiller for indoor installation without hydraulic circuit (pump, accumulator) incl. crank pan heating, phase monitoring. An external dry cooler unit is not included in the offer. Cooling capacity kW 53.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.25 Cooling water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 13.5 Heating capacity kW 67.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.51 Cooling water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 11.7 Refrigerant R 410A Electrical data: Voltage V 400,  ...

approved
dealer
Machine: MTA OCEAN Tech HOCT 200
New in: 2022
new

Heat pump / chiller - switchable - water / water cooled, Type: OCEAN Tech HOCT 200 MTA S.p.A. OCEAN Tech HOCT 200 are water-cooled heat pump / chiller for indoor installation without hydraulic circuit (pump, accumulator) incl. crank pan heating, phase monitoring. An external dry cooler unit is not included in the offer. Cooling capacity kW 53.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.25 Cooling water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 13.5 Heating capacity kW 67.9 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 9.51 Cooling water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 11.7 Refrigerant R 410A Electrical data: Voltage V 400,  ...

You didn't find your wanted machine? send wanted inquiry to all dealers (no registration necessary)