Process chiller / chiller air-cooled, Type: TAEevo Tech 101 P3 MTA S.p.A. TAEevo Tech 101 P3 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. And built-in P3 pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 30.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 5.22 Available pump pressure (bar) 2.51 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 14.4 Max. current (A) 24.58 Starting Current Circuit (A) 120.37 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 101 P3 MTA S.p.A. TAEevo Tech 101 P3 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. And built-in P3 pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 30.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 5.22 Available pump pressure (bar) 2.51 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 14.4 Max. current (A) 24.58 Starting Current Circuit (A) 120.37 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 251 P3-20 Refrigeration Machines, MTA S.p.A. TAEevo Tech 251P3-20 are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 350 ltr. and built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 50.4 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 8.59 Available pump pressure (bar) 2.61 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 26.99 Max. current (A) ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 251 P3-20 Refrigeration Machines, MTA S.p.A. TAEevo Tech 251P3-20 are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 350 ltr. and built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 50.4 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 8.59 Available pump pressure (bar) 2.61 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 26.99 Max. current (A) ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 301P3-FAN MTA S.p.A. TAEevo Tech 301 P3-FAN are air-cooled compact water chillers suitable for outdoor installation (from -20°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 350 ltr. , built-in P3 circulation pump electronic speed control of the fans. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 59.3 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow rate (m³/h) 10.1 Available pump pressure (bar) 3.14 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 3 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 301P3-FAN MTA S.p.A. TAEevo Tech 301 P3-FAN are air-cooled compact water chillers suitable for outdoor installation (from -20°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 350 ltr. , built-in P3 circulation pump electronic speed control of the fans. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 59.3 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow rate (m³/h) 10.1 Available pump pressure (bar) 3.14 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 3 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 602 P3 MTA S.p.A. TAEevo Tech 602P3 are compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, electronic expansion valve, buffer tank 500 ltr., built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 116 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 19.8 Available pump pressure (bar) 3.37 Ambient temperature °C 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 60.99 Max. current (A) 102.78 Starting Current Ci ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 602 P3 MTA S.p.A. TAEevo Tech 602P3 are compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, electronic expansion valve, buffer tank 500 ltr., built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 116 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 19.8 Available pump pressure (bar) 3.37 Ambient temperature °C 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 60.99 Max. current (A) 102.78 Starting Current Ci ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 1002 P3-20 M.T.A. S.p.A. TAEevo Tech 1002 P3-20 are air-cooled compact water chillers suitable for outdoor installation (from -20°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 950 ltr., condenser pressure control with speed-controlled fans and built-in P3 circulation pump. Cooling capacity kW 200 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 98.98 Max. Current (A) 167.46 Starting Current Circui ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 1002 P3-20 M.T.A. S.p.A. TAEevo Tech 1002 P3-20 are air-cooled compact water chillers suitable for outdoor installation (from -20°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 950 ltr., condenser pressure control with speed-controlled fans and built-in P3 circulation pump. Cooling capacity kW 200 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 98.98 Max. Current (A) 167.46 Starting Current Circui ...