We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Engine Brand: MAN, Conditie: USED, Engine Cooling Type: External Exchanger (eg. Keel Cooled) , Engine Color: Red , Turbo Type: Dry , Exhaust System: Watercooled , ECU Present?: no , Starter Voltage: 24 Volt , Injection Type: Mechanical Fuelpump , Generator KVA: 450 , Generator Hz: 50 , Generator Volts: 380/220 , Generator Amps: 684 , Generator Fases: 3 Fases , , https://www.hamofa.com/catalog/product/view/id/300552, , = More information =, , Empty weight: 3.800 kg, Type number: E2842E GENERATOR 450KVA
MODEL: EQ-D250200 ENGINE: Deutz BF6M1015C-LA G1A FREQUENCY (HZ): 50 VOLTAGE (V): 400 MAXIMUM POWER: 250(kVA) / 200(kW) STARTING: ELECTRIC CONTROL SYSTEM: SELF-CONTROL FUEL TYPE: DIESEL COOLING: WATER-COOLED WEIGHT: 3300kg DIMENSIONS L/W/HEIGHT (MM): 380012502000 The engines are new, complete including control, diesel tank, exhaust and batteries. Network monitoring, grid feed-in Soundproofed Immediately ready for use. Control: Deep Sea Electronics (DSE) / ComAp Alternator: Leroy-Somer / Stamford Additional: Automatic Transfer Switch (ATS) 63A/100A ABB & Schneider Disconnectors GenCloud Connect with a phone or computer Single-phase valve 50°C-55°C Radiator External Die ...
Engine Brand: OLYMPIAN, Conditie: CORE, Engine Cooling Type: Radiator Cooled (std) , Engine Color: Yellow , Turbo Type: Watercooled , Exhaust System: Watercooled , ECU Present?: yes , Starter Voltage: 24 Volt , Rated Power: 220 Kw, Rated Speed: 1500 Rpm, Injection Type: ECU (Electronic Control Unit) , Generator KVA: 250 , Generator Hz: 50 , Generator Volts: 400/230 , Generator Amps: 361 , Generator Fases: 3 Fases + Nul (4 totaal) , , https://www.hamofa.com/catalog/product/view/id/219106, , = More information =, , Empty weight: 2.500 kg, Type number: GEH250 GENERATOR 250KVA
BHKW in container with Cummins diesel engine Lorey Somer generator 250KVA 1500U / min 50 hertz Storm Steuerung, arrangement is equipped with emergency cooler zusaetzl. regularly waited to zeit 21000 company hours. arrangement is operational and available immediately. for other questions I stand to them to verfuegung under 01727265324
ENGINE: Man E2676LE202 FREQUENCY (HZ): 50 VOLTAGE(V): 400V/230V GENERATOR POWER: 250(kVA) / 200(kW) STARTING: ELECTRIC CONTROL SYSTEM: SELF-CONTROL FUEL TYPE: BIOGAS COOLING: WATER-COOLED WEIGHT: 4400kg DIMENSIONS L/W/HEIGHT (MM): 430013002000 The engines are new, complete including control, diesel tank, exhaust and batteries. Network monitoring, grid feed-in Soundproofed Immediately ready for use. Control: Deep Sea Electronics (DSE) Alternator: Leroy-Somer Additional: Automatic Transfer Switch (ATS) 63A/100A ABB & Schneider Disconnectors GenCloud Connect with a phone or computer Single-phase valve 50°C-55°C Radiator External Diesel Tank Lubricating Oil H ...
MODEL: EQ-VP250200 GENERATOR ENGINE: Volvo Penta TAD734GE FREQUENCY (HZ): 50 VOLTAGE(V): 400V/230V GENERATOR POWER: 250(kVA) / 200(kW) CYLINDERS: 6 FUEL TYPE: DIESEL COOLING: WATER-COOLED WEIGHT: 1950kg DIMENSIONS L/W/HEIGHT (MM): 260011001530 The engines are new, complete including control, diesel tank, exhaust and batteries. Network monitoring, grid feed-in Soundproofed Immediately ready for use. Control: Deep Sea Electronics (DSE) Alternator: Leroy-Somer Additional: Automatic Transfer Switch (ATS) 63A/100A ABB & Schneider Disconnectors GenCloud Connect with a phone or computer Single-phase valve 50°C-55°C Radiator External Diesel Tank Lubricating Oil Heater Water ...
Brand: MARELLI GENERATORS, Conditie: NEW, Generator KVA: 3550 , Generator Hz: 50 , Generator Volts: 400 , Generator Amps: 5124 , , https://www.hamofa.com/catalog/product/view/id/226794, , = More information =, , Type number: MJB630 LA4B24 LOSSE GEN 3550KVA ...
Diesel Power Plant MAN 57.9 MW / 50 Hz – year 2014 This diesel power plant consists of three identical 19.3 MW MAN 18V48/60 TS diesel generating units with auxiliaries. The engines are 500 rpm turbo charged with intercooling and they are installed on base frame forming a wet oil sump for engines. Diesel generators have been operated only approx. 5000 hours since new. Alternators are ABB made synchronous generators which are air-cooled, and they have their own lubrication oil system installed on concrete foundation and connected to the engines with flexible couplings. Engines are cooled with two separate cooling circuits connected to radiator cooling system. The control system is MAN Sa ...
SOITAAB CNC plasma cutting with 2 generators Year = 1998 Plant size: center distance = 6000 mm. Useful length 24 thousand mm. Implant length = 26 thousand mm. Speed allowed with double motorization 20 thousand mm./ min. Operating speed up to 5000/6000 mm./min Numerical control = OSAI 10/310 TFT with 10.4 "color monitor Plasma generators No. 2. - Hyperterm HT 2000 System in operation, complete with bench and NOVA VIT fume extractor complete with star valve, direct discharge of cutting dust in standard big bags.
Diesel Power Plant MAN 57.9 MW / 50 Hz – year 2014 This diesel power plant consists of three identical 19.3 MW MAN 18V48/60 TS diesel generating units with auxiliaries. The engines are 500 rpm turbo charged with intercooling and they are installed on base frame forming a wet oil sump for engines. Diesel generators have been operated only approx. 5000 hours since new. Alternators are ABB made synchronous generators which are air-cooled, and they have their own lubrication oil system installed on concrete foundation and connected to the engines with flexible couplings. Engines are cooled with two separate cooling circuits connected to radiator cooling system. The control system is MAN Sa ...