We use cookies to optimize our website for you and to be able to continuously improve it. By continuing to browse the site you are agreeing to our use of cookies.
Disagree
Heat pump / chiller air-cooled, reversible, reversible Type: CYGNUS TECH HCY 031 PT1 MTA S.P.A. CYGNUS TECH HCY 031 PT1 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crank pan heating, buffer tank and built-in P1 circulation pump. Heating capacity kW 11 Heating water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 1.93 Available pump pressure bar 1.36 Ambient temperature 7 °C Cooling capacity kW 9.22 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 1.56 Available pump pressure bar 1.54 Ambient temperature 35 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases ...
Heat pump / chiller air-cooled, reversible, reversible Type: CYGNUS TECH HCY 031 PT1 MTA S.P.A. CYGNUS TECH HCY 031 PT1 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crank pan heating, buffer tank and built-in P1 circulation pump. Heating capacity kW 11 Heating water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 1.93 Available pump pressure bar 1.36 Ambient temperature 7 °C Cooling capacity kW 9.22 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 1.56 Available pump pressure bar 1.54 Ambient temperature 35 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases ...
Heat pump / chiller, air-cooled, reversible Type: CYGNUS TECH HCY 051 MTA S.P.A. CYGNUS TECH HCY 051 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crankpan heating, (no pump, no tank). Cooling capacity kW 14,1 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 2.41 Ambient temperature 32 °C Heating capacity kW 15,4 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 2.66 Ambient temperature 7 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5,6 Max. current (A) 11.4 Starting current circuit (A) 71 Protectio ...
Heat pump / chiller, air-cooled, reversible Type: CYGNUS TECH HCY 051 MTA S.P.A. CYGNUS TECH HCY 051 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crankpan heating, (no pump, no tank). Cooling capacity kW 14,1 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 2.41 Ambient temperature 32 °C Heating capacity kW 15,4 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 2.66 Ambient temperature 7 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5,6 Max. current (A) 11.4 Starting current circuit (A) 71 Protectio ...
Chiller (cooling) unit Supplier: MTA (Italy) Type: TAE161-EVO 21 Kw Max. allowed pressure: 28 BAR Dimension: 18008001200 mm (LWH) Weight: 416 kg ...
Inverter heat pumps / chiller air-cooled reversible, Type: iHCY 020 PT1+FSH M.T.A. S.p.A. HCYGNUS TECH Inverter iHCY 020 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation down to -15 / -10°C suction temperature. Includes crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 6.43 Heating water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 1.13 Available pump pressure bar: 0.84 Ambient temperature +7 °C Cooling capacity kW 5.46 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 0.971 Available pump ...
Inverter heat pumps / chiller air-cooled reversible, Type: iHCY 020 PT1+FSH M.T.A. S.p.A. HCYGNUS TECH Inverter iHCY 020 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation down to -15 / -10°C suction temperature. Includes crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 6.43 Heating water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 1.13 Available pump pressure bar: 0.84 Ambient temperature +7 °C Cooling capacity kW 5.46 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 0.971 Available pump ...
Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 101 PT1+FSH MTA S.p.A. HCYGNUS TECH Inverter iHCY 101 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation down to -15 / -10°C suction temperature. Includes crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 25.2 Heating water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 4.4 Available pump pressure bar: 0.616 Ambient temperature +7 °C Cooling capacity kW 22.8 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 3.88 Available pum ...
Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 101 PT1+FSH MTA S.p.A. HCYGNUS TECH Inverter iHCY 101 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation down to -15 / -10°C suction temperature. Includes crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 25.2 Heating water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 4.4 Available pump pressure bar: 0.616 Ambient temperature +7 °C Cooling capacity kW 22.8 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 3.88 Available pum ...
Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 131 PT1+FSH MTA S.p.A. HCYGNUS TECH Inverter iHCY 131 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation up to -15 / -10°C intake temperature. Includes crankcase heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 35.5 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 6.18 Available pump pressure bar: 0.644 Ambient temperature °C +7 Cooling capacity kW 31.8 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 5.41 Avai ...