item-No.: 161125415 is deleted from the database!

10 similar machines:

approved
dealer
Machine: MTA CYGNUS TECH HCY 031 PT1
New in: 2022
new

Heat pump / chiller air-cooled, reversible, reversible Type: CYGNUS TECH HCY 031 PT1 MTA S.P.A. CYGNUS TECH HCY 031 PT1 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crank pan heating, buffer tank and built-in P1 circulation pump. Heating capacity kW 11 Heating water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 1.93 Available pump pressure bar 1.36 Ambient temperature 7 °C Cooling capacity kW 9.22 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 1.56 Available pump pressure bar 1.54 Ambient temperature 35 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases ...

approved
dealer
Machine: MTA CYGNUS TECH HCY 031 PT1
New in: 2022
new

Heat pump / chiller air-cooled, reversible, reversible Type: CYGNUS TECH HCY 031 PT1 MTA S.P.A. CYGNUS TECH HCY 031 PT1 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crank pan heating, buffer tank and built-in P1 circulation pump. Heating capacity kW 11 Heating water temp. Exit/Entry: 45 / 40°C Flow rate m³/h 1.93 Available pump pressure bar 1.36 Ambient temperature 7 °C Cooling capacity kW 9.22 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 1.56 Available pump pressure bar 1.54 Ambient temperature 35 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases ...

approved
dealer
Machine: MTA HCY 051
New in: 2021
used

Heat pump / chiller, air-cooled, reversible Type: CYGNUS TECH HCY 051 MTA S.P.A. CYGNUS TECH HCY 051 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crankpan heating, (no pump, no tank). Cooling capacity kW 14,1 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 2.41 Ambient temperature 32 °C Heating capacity kW 15,4 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 2.66 Ambient temperature 7 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5,6 Max. current (A) 11.4 Starting current circuit (A) 71 Protectio ...

approved
dealer
Machine: MTA HCY 051
New in: 2021
used

Heat pump / chiller, air-cooled, reversible Type: CYGNUS TECH HCY 051 MTA S.P.A. CYGNUS TECH HCY 051 are compact heat pumps / water chillers designed for outdoor installation up to -10°C suction temperature. Including crankpan heating, (no pump, no tank). Cooling capacity kW 14,1 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 2.41 Ambient temperature 32 °C Heating capacity kW 15,4 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 2.66 Ambient temperature 7 °C Refrigerant R 410A Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3 Max. power consumption (kW) 5,6 Max. current (A) 11.4 Starting current circuit (A) 71 Protectio ...

approved
dealer
Machine: MTA Chiller
used
Seller: Land-uk Andrew Isaacs Machinery International Ltd
VS

Chiller (cooling) unit Supplier: MTA (Italy) Type: TAE161-EVO 21 Kw Max. allowed pressure: 28 BAR Dimension: 18008001200 mm (LWH) Weight: 416 kg  ...

  • more information

approved
dealer
Machine: MTA iHCY 020 PT1+FSH
New in: 2022
new

Inverter heat pumps / chiller air-cooled reversible, Type: iHCY 020 PT1+FSH M.T.A. S.p.A. HCYGNUS TECH Inverter iHCY 020 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation down to -15 / -10°C suction temperature. Includes crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 6.43 Heating water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 1.13 Available pump pressure bar: 0.84 Ambient temperature +7 °C Cooling capacity kW 5.46 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 0.971 Available pump ...

approved
dealer
Machine: MTA iHCY 020 PT1+FSH
New in: 2022
new

Inverter heat pumps / chiller air-cooled reversible, Type: iHCY 020 PT1+FSH M.T.A. S.p.A. HCYGNUS TECH Inverter iHCY 020 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation down to -15 / -10°C suction temperature. Includes crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 6.43 Heating water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 1.13 Available pump pressure bar: 0.84 Ambient temperature +7 °C Cooling capacity kW 5.46 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 0.971 Available pump ...

approved
dealer
Machine: MTA Cycnus iHCY 101 PT1+FSH
New in: 2022
new

Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 101 PT1+FSH MTA S.p.A. HCYGNUS TECH Inverter iHCY 101 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation down to -15 / -10°C suction temperature. Includes crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 25.2 Heating water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 4.4 Available pump pressure bar: 0.616 Ambient temperature +7 °C Cooling capacity kW 22.8 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 3.88 Available pum ...

approved
dealer
Machine: MTA Cycnus iHCY 101 PT1+FSH
New in: 2022
new

Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 101 PT1+FSH MTA S.p.A. HCYGNUS TECH Inverter iHCY 101 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation down to -15 / -10°C suction temperature. Includes crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 25.2 Heating water temp. Exit/Entry: 45 / 40°C Volume flow m³/h 4.4 Available pump pressure bar: 0.616 Ambient temperature +7 °C Cooling capacity kW 22.8 Cold water temp. Exit/Entry: 7 / 12°C Flow rate m³/h 3.88 Available pum ...

approved
dealer
Machine: MTA Cycnus iHCY 131 PT1+FSH
New in: 2022
new

Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 131 PT1+FSH MTA S.p.A. HCYGNUS TECH Inverter iHCY 131 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation up to -15 / -10°C intake temperature. Includes crankcase heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 35.5 Heating water temp. Exit/Entry: 45 / 40°C Volumetric flow m³/h 6.18 Available pump pressure bar: 0.644 Ambient temperature °C +7 Cooling capacity kW 31.8 Cold water temp. Exit/ Entry: 7 / 12°C Volumetric flow m³/h 5.41 Avai ...

You didn't find your wanted machine? send wanted inquiry to all dealers (no registration necessary)